Viewed On: 01/23/2004 10:40:06, attachments at bottom of page. Save As HTML | Print This Page
Problem Record Details for STEREO-xxx-007
Stage: PR
Date/Time Submitted: 01/21/2004 07:34
Project: STEREO
Submittor Info:
Name: Pam Hopkins
Code: 303.0
Phone: +1 301 286-1059
Email: phopkins@pop400.gsfc.nasa.gov
Spacecraft: STEREO Ahead Spacecraft (STEREO-A)
Subsystem/Instrument: IMPACT
Component: SEP
Date/Time of Actual Problem: 01/21/2004 00:00 Assembly: [left blank]
WOA#: xxx Event/Operation Line Number: 030
Configuration Type: Flight Item Number: GD2054170
Item Revision: - Serial Number: 001,002
Software Version: [left blank]  
Problem Description:
SIT Energy Board, connector p/n 055 939-9039-AR6 does not fit into the connector location on the PWB. The leads (2) of the connector measure .043", the hole diameter in the board is .040".
Problem Addendum 1 (by Lil Reichenthal on 01/22/2004 15:53):
This fix applies to both SIT Energy Boards (Spacecraft A and B)
Problem Addendum 2 (by Pam Hopkins on 01/22/2004 16:00):
WOA-663-026
Required Approvals for Closure: (One signature(s) required from Project Side (minimum role PDL) AND One signature(s) required from QA Side (minimum role QE)
Fields with a gray background were hidden by the project at the time this PR/PFR was submitted.
[Active Project Revision,Revision PR was created in] = [1,1]
Attachments:
Disposition steps (attached by M.Haynes on 01/22/2004 15:44)